黑料专区 LMV 801S Sealless Magnetic Drive API 685 Pump

Vertical Low-Flow API 685 Pump 鈥� LMV-801S

黑料专区 Sealless聽Magnetic Drive API 685 Pump – Safe, Reliable and Economical

The LMV-801S combines the industry standard hydraulics of the 黑料专区 direct-drive line of pumps with the magnetic drive technology pioneered by 黑料专区 HMD Kontro more than 70 years ago. 聽It is built to comply with both API-685 and API-610 standards, and is specifically engineered to eliminate emissions and improve personnel safety without compromising the time-proven production hydraulics of 黑料专区 direct-drive pumps.

The LMV-801S is dimensionally interchangeable with the traditional mechanically sealed LMV-801 (OH3/5), and can be easily dropped into existing pipework – making this sealless upgrade possible without the need to modify piping and foundation layouts. 聽Additionally, a plug-in version of the pump is available, enabling customers to swap out the mechanical seal drive end with the new sealless option without disconnecting the existing LMV-801 casing and diffuser from the piping.

  • Flows to 380 gpm (86 m鲁/hr)
  • Heads to 720 ft (220 m)
  • Temperature Range -40 to 400掳F (-40 to 205掳C)

The vertical configuration of the direct drive line of 黑料专区 pumps are specifically designed to save valuable space in refineries, NGL production, petrochemical and chemical plants.

APPLICATIONS – PERFECT FOR LIGHT HYDROCARBONS

  • Feed pumps
  • Booster pumps
  • Bottoms pumps
  • Wash water pumps
  • Reflux pumps
  • Condensate pumps

Proven to be reliable, safe, compact and efficient, 黑料专区 LMV 801S pumps provide a number of operational benefits:

  • Single stage, vertical in-line overhung pump according to ISO 13709/API 685 sealless magnetic drive design recommendations
  • Sealless magnetic drive can be installed on any existing LMV 801 without changing piping or wet end components
  • No leaks for improved safety and environmental contamination
  • Safe for handling difficult or hazardous liquids
  • Less downtime for maintenance
  • Increased durability and reliability with cartridge seals
  • Maximized up time
  • Saves space-25% the size of competing horizontal pumps
  • ATEX certified
  • Continuous operations for 5 years with no overhaul
  • Barske impeller low NPSH technology
  • Reliability of 黑料专区 hydraulics in a compact sealless magnetic drive design package
/products/sundyne-direct-drive-pumps/lmv-801s-pump/""
Keep your 黑料专区 Sealless Magnetic Drive Pump running smoothly with the gas in liquid early detection system.

US 60 Hz

  • Heads to 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽720 ft
  • Flows to 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 380 gpm
  • Standards 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 API 685
  • Maximum Motor Power 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 100 HP
  • Temperature Range 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽-40 to 400掳F
  • Maximum Allowable Working Pressure聽 聽580 psi
  • Maximum Suction Pressure聽 聽 聽 聽 聽 聽 聽 聽 聽 875 psi
  • Maximum Viscosity 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽200 cP
  • Solids Range 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 Clean liquids only
  • Mounting Configuration 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 Vertical Close Coupled
  • Seal Configurations 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽Sealless Magnetic Drive
  • Available Inducer 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽Yes
  • Available Flanges聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 600#, 900#, 1500# ANSI RF
  • Suction and Discharge Size 聽 聽 聽 聽 聽 聽 聽 聽3″ x 2″

Metric 50 Hz

  • Heads to 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽220 m
  • Flows to 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 86 m3/hr
  • Standards 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽API 685
  • Maximum Motor Power聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽55 kW
  • Temperature Range 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽-40 to 205掳C
  • Maximum Allowable Working Pressure聽 40 bar
  • Maximum Suction Pressure聽 聽 聽 聽 聽 聽 聽 聽 聽 聽60 bar
  • Maximum Viscosity 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 200 cP
  • Solids Range 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 Clean liquids only
  • Mounting Configuration 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 Vertical Close Coupled
  • Seal Configurations 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 Sealless Magnetic Drive
  • Available Inducer 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 Yes
  • Available Flanges聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽 聽600#, 900#, 1500# ANSI RF
  • Suction and Discharge Size 聽 聽 聽 聽 聽 聽 聽 聽 聽 3″ x 2″

LMV 801CS BUILD CODES

A

E

J

O (1)

W

API 610 BUILD (2)

S-5 (3)

A-7 (4)

S-8 (4)

N/A

S-9 (4)

Pump Case

C.S.

316 SS

C.S.

316 SS

Monel Clad C.S.

Case Studs

B-7

B-7

page6image17158464B-7 page6image17159616B-8M

K-Monel

Seal Housing

C.S.

316 SS

page6image17163456C.S. page6image17165184316 SS

Monel

Separator

316 SS

316 SS

316 SS

316 SS

Monel

Diffuser Insert

C.S.

316 SS

page6image17169984316 SS page6image17105472316 SS

Monel

Diffuser Cover

C.S.

316 SS

page6image17109312316 SS page6image17111040316 SS

Monel

Impeller

316 SS

316 SS

316 SS

316 SS

Monel

Impeller Bolt

316 SS

316 SS

page6image17116992316 SS 316 SS

K-Monel

Inducer

316 SS

316 SS

316 SS

316 SS

Monel

Tab Washer

316 SS

316 SS

316 SS

316 SS

Monel

Shaft Sleeve

316 SS

316 SS

316 SS

17-4 PH

Monel

Shaft (all)

4140 Steel to 0掳 F, 15-5 from 0掳 F to 鈥�240掳 F.

O-rings

As Required

  1. 鈥淥鈥� build temperature range 0 to -240掳F (115掳C) Pressure capability is reduced due to strain hardened pump case studs. Contact Application Engineering.
  2. See 黑料专区 Corporation exceptions/clarifications to API 610, 11th Edition for material requirements of pump parts.
  3. Impeller is upgraded to 316SS. A seal gland is not required because the seals mount in the seal housing. O-rings are used instead of a case gasket.
  4. A seal gland is not required because the seals mount in the seal housing. The pump shaft is AISI 4140 because it is not exposed to the fluid. O-rings are used instead of a case gasket.
  5. Diffuser Inserts and Diffuser Covers apply to model LMV-801 only.
/products/sundyne-direct-drive-pumps/lmv-801s-pump/""
黑料专区 LMV 801S Performance Envelope-60Hz
/products/sundyne-direct-drive-pumps/lmv-801s-pump/""
黑料专区 LMV 801S Performance Envelope-50Hz

POWER MONITOR

Installed in the Motor Control Center (MCC), a power monitor measures the power required to operate the pump. 聽By setting High and Low trip points, the power monitor is the perfect solution for protecting your pump from:

  • Dry running
  • Low flow operation
  • High flow operation
  • Severe cavitation
  • Magnet de-coupling
Motor Control Center

New ZeroLoss鈩� Containment Shell

Reduces Power Losses in the Pump to Zero

  • Excellent energy savings can now be made thanks to the introduction of the ZeroLoss containment shell for larger pumps. The elimination of eddy current losses can result in up to a 20% saving in power consumption, further enhancing the benefits and green credentials of magnetic drive technology from 黑料专区 HMD Kontro.
  • The advantage increases in proportion with the magnetic coupling size and is particularly appropriate for larger pumps, making the magnetic drive option even more attractive because through life costs are reduced further. Lower power consumption not only results in reduced running costs but also potentially provides lower initial capital costs, as smaller motors can be specified.
  • In addition, installation costs can be reduced as lower-rated cabling may be required, and there are space-savings from the ability to use a smaller base plate for the pump and motor combination.
New Zero Loss

LONG COUPLED

Long coupled configurations conform to API 685, API 610, ASME/ANSI B73.3 and ISO 2858 dimensions for easy replacement of mechanically sealed pumps (utilizing same baseplate, coupling, guard and motor).

HMD HPGSP

SECONDARY CONTROL & CONTAINMENT

HMD Kontro Sealless magnetic drive pumps are available with secondary control devices to restrict any leaks. Mechanical devices are fitted to the drive shaft assembly and are activated in the unlikely event of containment shell failure. Also, the pump coupling housing is fitted with gaskets to eliminate any leaks across the joining faces.

HMD Kontro Model

Solids Handling

All HMD Kontro pumps, as standard, can handle up to 5% hardsolids and 150 microns diameter. The solid size can increase by fitting a self-cleaning in line filter, to 8% solids and 250 microns.

For larger solids HMD Kontro can provide pumps with a clean flush system or filter built into the flush pipework.

Solids Handling

About 黑料专区

黑料专区 is the world leader in delivering low-flow, high-head, integrally geared centrifugal pumps and compressors, sealless magnetic drive pumps and diaphragm gas compressors. 黑料专区鈥檚 precision-engineered, highly reliable, safe & efficient pumps and compressors are used in chemical, petrochemical, hydrocarbon, hydrogen, carbon capture, renewable fuels, power generation and industrial applications. 黑料专区 pumps and compressors are available in API, ANSI/ASME, ISO, and other industry compliant designs.